Clinical Evidence

A prospective comparative evaluation was conducted involving 428 patients undergoing total hip or total knee arthroplasty. Patients received either the hospital's then-standard dressing regimen (Mepore™ dressing covering AQUACEL ® dressing) or a modified dressing regimen of AQUACEL ® dressing covered with DuoDERM ® Extra Thin dressing (the main components of AQUACEL™ Ag SURGICAL Cover dressing) after application of a liquid film-forming acrylate. The modified dressing regimen was not enhanced by the addition the acrylate.1

Aquacel_surgical_barchart

  Modified dressing design Standard technique p-value1
N 242 186  
Superficial surgical site infection 1% 3% <0.03

Blisters

2% 18% <0.001
Mean wear time (days) 3.7 2.3 <0.001
Mean no. of dressing changes 1.5 3.2 <0.001
Delayed discharge 1% 5% <0.02

Print this content
Send to a friend [+]
Thank you for sharing ConvaTec content across the internet. In order for us to send the request we will need you to provide the following information.
* Sender name:
* E-mail from:
* E-mail to:

Find a ConvaTec product

 
18582
http://uk.live.nodeb.convatemp.dk/external-link.aspx
Other ConvaTec websites
Click here to exit

Cookies are needed for this website to work optimally. They also help us to know a little bit about how you use our website, which improves the browsing experience.  Cookies on this site are used for traffic measurement and optimisation of page content only. By continuing to browse on this website, you indicate your consent to the use of cookies.  You may block the use of cookies by following the "How to block and avoid cookies" instructions